| Temperature Drift | +/- 0.05 %/°C | Voltage Drift | +/- 0.2 %/V |
| Repeat Accuracy | +/- 0.5 % IEC 61812-1 | Setting Accuracy Of Time Delay | +/- 10 % of full scale 25 °C IEC 61812-1 |
| Ambient Air Temp For Storage | -22…140 °F (-30…60 °C) | Operating Temperature | -4…140 °F (-20…60 °C) |
| Product Weight | 0.15 lb(US) (0.07 kg) | Tightening Torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Power Consumption In W | 0.6 W 24 V DC | Width | 0.69 in (17.5 mm) |
| Voltage Range | 0.85...1.1 Us | Power Consumption In Va | 0…32 VA 240 V AC |
| Contacts Type And Composition | 1 C/O | Release Of Input Voltage | 10 V |
| Operating Frequency | 10 Hz | Minimum Switching Current | 10 mA at 5 V DC |
| Control Signal Pulse Width | 100 ms with load in parallel typical || 30 ms typical | On-load Factor | 100 % |
| Power On Delay | 100 ms | Electrical Durability | 100000 cycles resistive 8 A 250 V AC |
| Mechanical Durability | 10000000 cycles | Reset Time | 120 ms on de-energisation typical |
| Shock Resistance | 15 gn 11 ms IEC 60068-2-27 | Dielectric Strength | 2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1 |
| Depth | 2.83 in (72 mm) | Vibration Resistance | 20 m/s² 10…150 Hz)IEC 60068-2-6 |
| Immunity To Microbreaks | 20 ms | Breaking Capacity | 2000 VA |
| [us] Rated Supply Voltage3 | 24...240 V AC 50/60 Hz || 24 V DC | Maximum Switching Voltage | 250 V AC |
| Height | 3.54 in (90 mm) | Mounting Support | 35 mm DIN rail conforming to EN/IEC 60715 |
| Creepage Distance | 4 kV/3 IEC 60664-1 | Rated Impulse Voltage | 5 kV 1.2/50 µs |
| Supply Frequency | 50...60 Hz +/- 5 % | Time Delay Range | 6...60 min || 1...10 h || 0.1...1 s || 1...10 s || 1...10 min || 10...100 h || 6...60 s |
| Nominal Output Current | 8 A | Maximum Switching Current | 8 A AC/DC |
| Relative Humidity | 93 % without condensation IEC 60068-2-30 | Time Delay Type | A, Ac, At, B, Bw, C, D, Di, H, Ht |
| Mounting Position | Any position in relation to normal vertical mounting plane | Safety Reliability Data | B10d = 270000 || MTTFd = 296.8 years |
| Contacts Material | Cadmium free | Markings | CE |
| Certifications / Standards | CSA || GL || CULus | Electromagnetic Compatibility | Electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2 || Electrostatic discha |
| Green Premium Status | Green Premium product | Ip Degree Of Protection | IP20 IEC 60529 terminal block) || IP40 (housing) conforming to IEC 60529 || IP50 IEC 60529 front pan |
| Local Signalling | LED indicator on steady: relay energised, no timing in progress || LED indicator 80 % ON and 20 % OF | Type | Modular timing relay |
| Functionality | Multifunction | Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| Compatibility Code | RE17 | Device Short Name | RE17R |
| Discrete Output Type | Relay | Brand | Schneider Electric |
| Terminal Connection | Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end || Screw terminals, | Control Type | Selector switch front panel |
| Housing Material | Self-extinguishing | Mercury Free | Yes |
| Range Of Product | Zelio Time | | |